You are here:

Accreditation scope for

TEST 266

Bergen kommune

Bergen Vann - Vannlaboratoriet

Spelhaugen 22
5147 Fyllingsdalen

Telephone: 55 56 78 64 / 948 26 782 / 920 65 798
E-mail: vannlaboratoriet@bergen.kommune.no
Internet: http://www.bergenvann.com
The laboratory meets the requirements in

NS-EN ISO/IEC 17025:2017




Accreditation includes:
The administrative / geographical unit:
Bergen Vann - Vannlaboratoriet
Spelhaugen 22
5147 Fyllingsdalen



Permanent facility
P12 Chemical analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Pure water
Parameter
Colour
Reference standard
NS-EN ISO 7887
Internal method identity
32646
Comment
Robot analyzer. Method C.
Object
Clean water
Parameter
pH
Reference standard
NS-EN ISO 10523
Internal method identity
32646
Comment
Analysis robot
Object
Pure water
Parameter
UV transmission
Reference standard
NS 9462
Internal method identity
32646
Comment
Analysis robot
Object
Clean water
Parameter
Determination of turbidity
Reference standard
NS-EN ISO 7027-1
Internal method identity
32637
Comment
Spectophotometry Quantitative.
Object
Clean water and sea water
Parameter
Ectrical conductivity
Reference standard
NS-EN 27888
Internal method identity
32646
Comment
Robot analyzer
P16 Microbiological analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
All types of water
Parameter
Enumeration of Clostridium perfringens
Reference standard
NS-EN ISO 14189
Internal method identity
32545
Comment
Method using membrane filtration
Object
All types of water
Parameter
Culturable microorganisms
Reference standard
NS-EN ISO 6222
Internal method identity
32546
Comment
Plate count at 22 C
Object
Clean water and seawater
Parameter
Enumeration of Intestinal Enterococci
Reference standard
ISO 7899-2
Internal method identity
32547
Comment
Membrane filtration
Object
Pure water, sea water and waste water
Parameter
Enumeration of Escherichia coli and coliform bacteria
Reference standard
NS-EN ISO 9308-2
Internal method identity
32548
Comment
MPN-method (Colilert)
Object
Waters with low bacterial background flora
Parameter
Enumeration of Escherichia coli and coliform bacteria
Reference standard
NS-EN ISO 9308-1/A1
Internal method identity
32534
Comment
Membrane filtration