Energy (and power)
Active, Reactive, Apparent
1 and 3 phase
Range
See remark
Uncertainty (CMC)
0,040 %
Remarks/ref. to internal procedure: BL08.07.03 Based on "Statnetts krav til måling av sentralnettsutveksling v.1.1(2016)" and includes evaluation of metering point.
cosφ = -1 til 1
f = 45-70Hz
I = 0,01-120A
U = 5-520V
DC power, calibration of meter
Range
1 to 100 mW
Uncertainty (CMC)
0,029 - 0,026 %
Range
0,1 to 100 W
Uncertainty (CMC)
0,026 - 0,064 %
Range
0,1 to 21 kW
Uncertainty (CMC)
0,064 - 0,16 %
Remarks/ref. to internal procedure: BL08.04.01
Capacitance, calibration of meter
Range
0,19 to 1,1 nF
Uncertainty (CMC)
4,5 - 1,1 %, 10-10k Hz
Range
1,1 to 3,3 nF
Uncertainty (CMC)
1,1 - 0,62 %, 10-3k Hz
Range
3,3 to 330 nF
Uncertainty (CMC)
0,62 - 0,26 %, 10-1k Hz
Range
0,33 to 1,1 µF
Uncertainty (CMC)
0,26 %, 10-600 Hz
Range
1,1 to 3,3 µF
Uncertainty (CMC)
0,26 %, 10-300 Hz
Range
3,3 to 11 µF
Uncertainty (CMC)
0,26 %, 10-150 Hz
Range
11 to 33 µF
Uncertainty (CMC)
0,26 - 0,38%, 10-120 Hz
Range
33 to 110 µF
Uncertainty (CMC)
0,38 - 0,42%, 10-80 Hz
Range
110 to 330 µF
Uncertainty (CMC)
0,42 %, 0-50 Hz
Range
0,33 to 1,1 mF
Uncertainty (CMC)
0,42 %, 0-20 Hz
Range
1,1 to 3,3 mF
Uncertainty (CMC)
0,42 %, 0-6 Hz
Range
3,3 to 11 mF
Uncertainty (CMC)
0,42 %, 0-2 Hz
Range
11 to 33 mF
Uncertainty (CMC)
0,42 - 0,65 %, 0-0.6 Hz
Range
33 to 110 mF
Uncertainty (CMC)
0,65 - 0,92 %, 0-0.2 Hz
Remarks/ref. to internal procedure: BL08.04.01
Resistance, measurement
Range
1 to 100 mohm
Uncertainty (CMC)
0,47 - 11 µohm
Range
0,1 to 17,4 ohm
Uncertainty (CMC)
0,011 - 1,4 mohm
Range
17,4 to 400 ohm
Uncertainty (CMC)
0,20 - 3,1 mohm
Range
0,4 to 1 kohm
Uncertainty (CMC)
29 - 72 mohm
Range
1 to 100 kohm
Uncertainty (CMC)
0,072 - 24 ohm
Range
0,1 to 1 Mohm
Uncertainty (CMC)
0,024 - 2 kohm
Remarks/ref. to internal procedure: BL08.06.01
Resistance, calibration of meter
Range
0 ohm
Uncertainty (CMC)
39 µohm
Range
0 to 1 ohm
Uncertainty (CMC)
85 µohm
Range
1 to 1,9 ohm
Uncertainty (CMC)
160 µohm
Range
1,9 to 10 ohm
Uncertainty (CMC)
250 µohm
Range
10 to 25ohm
Uncertainty (CMC)
74 µohm
Range
25 to 19ohm
Uncertainty (CMC)
450 µohm
Range
19 to 100ohm
Uncertainty (CMC)
180 µohm
Range
100 to 190ohm
Uncertainty (CMC)
2,9 mohm
Range
190 to 1kohm
Uncertainty (CMC)
16 mohm
Range
1 to 1,9kohm
Uncertainty (CMC)
30 mohm
Range
1,9 to 10kohm
Uncertainty (CMC)
160 mohm
Range
10 to 19kohm
Uncertainty (CMC)
300 mohm
Range
19 to 100kohm
Uncertainty (CMC)
1,6 ohm
Range
100 to 1Mohm
Uncertainty (CMC)
3,0 ohm
Range
1 to 1,9Mohm
Uncertainty (CMC)
35 ohm
Range
1,9 to 10Mohm
Uncertainty (CMC)
350 ohm
Range
10 to 19Mohm
Uncertainty (CMC)
810 ohm
Range
19 to 100Mohm
Uncertainty (CMC)
10 kohm
Range
0,1 to 1,1Gohm
Uncertainty (CMC)
0,4 - 12 %
Remarks/ref. to internal procedure: BL08.04.01
AC Voltage, calibration of meter
Range
0 to 2,2 Mv
Uncertainty (CMC)
7,8 - 8,2 µV, 40-20k Hz
Range
2,2 to 22 mV
Uncertainty (CMC)
9,7 - 13 µV, 40-20k Hz
Range
22 to 220 mV
Uncertainty (CMC)
9,6 - 27 µV, 40-20k Hz
Range
0,22 to 2,2 V
Uncertainty (CMC)
20 - 150 µV, 40-20k Hz
Range
2,2 to 22 V
Uncertainty (CMC)
0,2 - 1,5 mV, 40-20k Hz
Range
22 to 220 V
Uncertainty (CMC)
2,3 - 16 mV, 40-20k Hz
Range
220 to 1100 V
Uncertainty (CMC)
19 - 91 mV, 40-01k Hz
Remarks/ref. to internal procedure: BL08.04.01
DC Current
Range
0 to 120 µA
Uncertainty (CMC)
0,1 - 2,5 nA
Range
0,12 to 1,2 mA
Uncertainty (CMC)
7,4 - 29 nA
Range
1,2 to 12 mA
Uncertainty (CMC)
0,074 - 0,29 µA
Range
12 to 120 mA
Uncertainty (CMC)
0,9 - 4,7 µA
Range
0,12 to 1,0 A
Uncertainty (CMC)
0,023 - 0,12mA
Remarks/ref. to internal procedure: BL08.05.01
DC Voltage
Range
0 to 120 mV
Uncertainty (CMC)
1,0 - 1,6 µV
Range
0,12 to 1,2 V
Uncertainty (CMC)
1,5 - 5,8 µV
Range
1,2 to 12 V
Uncertainty (CMC)
7,0 - 50 µV
Range
12 to 120 V
Uncertainty (CMC)
0,10 - 0,75 mV
Range
120 to 1000 V
Uncertainty (CMC)
0,82 - 6,1 mV
Remarks/ref. to internal procedure: BL08.05.01
DC Resistance
Range
0 to 12 ohm
Uncertainty (CMC)
0,05 - 0,23 mohm
Range
12 to 120 ohm
Uncertainty (CMC)
0,64 - 1,9 mohm
Range
0,12 to 1,2 kohm
Uncertainty (CMC)
1,7 - 13 mohm
Range
1,2 to 12 kohm
Uncertainty (CMC)
0,020 - 0,13 ohm
Range
12 to 120 kohm
Uncertainty (CMC)
0,20 - 1,3 ohm
Range
0,12 to 1,2 Mohm
Uncertainty (CMC)
4,0 - 20 ohm
Range
1,2 to 12 Mohm
Uncertainty (CMC)
160 - 700 ohm
Remarks/ref. to internal procedure: BL08.06.03
Energy (and power) Active, Reactive, Apparent 1 and 3 phase
Range
See remark
Uncertainty (CMC)
0,020 %
Remarks/ref. to internal procedure: BL08.07.04
cosφ = -1 til 1
f = 45-70Hz
I = 0,01-120A
U = 5-520V
DC Resistance, calibration of source
Range
0 to 12 ohm
Uncertainty (CMC)
0,05 - 0,23 mohm
BL08.06.03
Range
12 to 120 ohm
Uncertainty (CMC)
0,64 - 1,9 mohm
Range
0,12 to 1,2 kohm
Uncertainty (CMC)
1,7 - 13 mohm
Range
1,2 to 12 kohm
Uncertainty (CMC)
0,020 - 0,13 ohm
Range
12 to 120 kohm
Uncertainty (CMC)
0,20 - 1,3 ohm
Range
0,12 to 1,2 Mohm
Uncertainty (CMC)
4,0 - 20 ohm
Range
1,2 to 12 Mohm
Uncertainty (CMC)
160 - 700 ohm
Remarks/ref. to internal procedure: BL08.06.03
DC Voltage, calibration of source
Range
0 to 120 mV
Uncertainty (CMC)
1 - 1,6 µV
Range
0,12 to 1,2 V
Uncertainty (CMC)
1,5 - 5,8 µV
Range
1,2 to 12 V
Uncertainty (CMC)
7,0 - 50 µV
Range
12 to 120 V
Uncertainty (CMC)
0,10 - 0,75 mV
Range
120 to 1000 V
Uncertainty (CMC)
0,82 - 6,1 mV
Remarks/ref. to internal procedure: BL08.05.01
DC Voltage, calibration of meter
Range
0 to 220 mV
Uncertainty (CMC)
0,68 - 2,9 µV
Range
0,22 to 2,2 V
Uncertainty (CMC)
3,0 - 15 µV
Range
2,2 to 11 V
Uncertainty (CMC)
17 - 71 µV
Range
11 to 22 V
Uncertainty (CMC)
74 - 140 µV
Range
22 to 220 V
Uncertainty (CMC)
0,23 - 1,6 mV
Range
220 to 1100 V
Uncertainty (CMC)
2,3 - 9,8 mV
Remarks/ref. to internal procedure: BL08.04.01
DC Current, calibration of source
Range
0 to 120 µA
Uncertainty (CMC)
0,1 - 2,5 nA
Range
0,12 to 1,2 mA
Uncertainty (CMC)
7,4 - 29 nA
Range
1,2 to 12 mA
Uncertainty (CMC)
0,074 - 0,29 µA
Range
12 to 120 mA
Uncertainty (CMC)
0,90 - 4,7 µA
Range
0,12 to 1 A
Uncertainty (CMC)
0,023 - 0,12 mA
Remarks/ref. to internal procedure: BL08.05.01
DC Current, calibration of meter
Range
0 to 220 µA
Uncertainty (CMC)
7,8 - 18 nA
Range
0,22 to 2,2 mA
Uncertainty (CMC)
18 - 110 nA
Range
2,2 to 22 mA
Uncertainty (CMC)
0,18 - 1,1 µA
Range
22 to 220 mA
Uncertainty (CMC)
2,0 - 13 µA
Range
0,22 to 2,2 A
Uncertainty (CMC)
39 - 185 µA
Range
2,2 to 11 A
Uncertainty (CMC)
0,99 - 3,4 mA
Range
11 to 20,5 A
Uncertainty (CMC)
9,1 - 16 mA
Range
20,5 to 1025 A
Uncertainty (CMC)
0,092 - 4,8 A
Remarks/ref. to internal procedure: BL08.04.01
Voltage ratio
Range
HF Powermeter DC verification
Uncertainty (CMC)
Range
0 to 100 % scale
Uncertainty (CMC)
0,06 - 0,6 % point
Zero carryover (0% scale) and instrumentation (100 % scale)
Remarks/ref. to internal procedure: MP 220
AC Current, calibration of meter
Range
0 to 220 µA
Uncertainty (CMC)
31 - 86 nA, 40-1k Hz
Range
0,22 to 2,2 mA
Uncertainty (CMC)
0,12 - 0,61 µA, 40-1k Hz
Range
2,2 to 22 mA
Uncertainty (CMC)
0,87 - 4,5 µA, 40-1k Hz
Range
22 to 220 mA
Uncertainty (CMC)
12 - 68 µA, 40-1k Hz
Range
0,22 to 2,2 A
Uncertainty (CMC)
0,16 - 1,3 µA, 20-1k Hz
Range
2,2 to 11 A
Uncertainty (CMC)
1,3 - 6,1 µA, 40-1k Hz
Range
11 to 20,5 A
Uncertainty (CMC)
14 - 23 mA, 45-100 Hz
Range
20,5 to 110 A
Uncertainty (CMC)
93 - 500 mA, 20-1k Hz
Range
110 to 550 A
Uncertainty (CMC)
0,50 - 2,5 A, 40-1k Hz
Range
550 to 1025 A
Uncertainty (CMC)
2,6 - 4,8 A, 45-100 Hz
Remarks/ref. to internal procedure: BL08.04.01
Energy (and power) Active, Reactive, Apparent
1 and 3 phase
Range
See remark
Uncertainty (CMC)
0,10 %
Remarks/ref. to internal procedure: BL08.07.01
cosφ = -1 til 1
f = 45 Hz til 70Hz
I = 0,01 A til 120 A
U = 5 V til 520 V
Power, using power sensor
Range
0,9 to 1,1 mW
Uncertainty (CMC)
3,1 µW
49 - 51 MHz in 50 ohm system and N connector.
Range
+20 to -70 dBm
Uncertainty (CMC)
0,01 - 0,69 dB
100 kHz to 18 GHz in 50 ohm system and N connector
Range
+20 to -30 dBm
Uncertainty (CMC)
0,01 - 1,48 dB
10 MHz to 26.5 GHz in 50 ohm system and 3.5 mm connector
Remarks/ref. to internal procedure: MP 210 Measured using Power Sensor
Attenuation
Range
0 to 50 dB
Uncertainty (CMC)
0,02 - 0,46 dB
100 kHz to 18 GHz in 50 ohm system with N connector
Remarks/ref. to internal procedure: MP 212 RF substitution
Cal Factor for power sensor with N-connector
Range
80 to 110 %
Uncertainty (CMC)
0,3 - 0,8 % points
100 kHz to 18 GHz in 50 ohm system and N connector
Range
80 to 110 %
Uncertainty (CMC)
Range
Uncertainty (CMC)
0,4 - 1,8 % points
10 MHz to 26,5 GHz in 50 ohm system and 3,5 mm connector
Remarks/ref. to internal procedure: MP 213
Power, generated level using power splitter
Range
1 mW (0 dBm)
Uncertainty (CMC)
3,1 µW
50 MHz in 50 ohm system with N connector
Range
+20 to - 70 dBm
Uncertainty (CMC)
0,04 - 0,68 dB
100 kHz to 18 GHz in 50 ohm system and N connector. The uncertainty will be greater if adaptors must be used.
Range
+10 to - 30 dBm
Uncertainty (CMC)
0,02 - 1,48 dB
10 MHz to 26.5 GHz in 50 ohm system and 3.5 mm connector.
Remarks/ref. to internal procedure: MP 211
Energy (and power) Active,
Reactive, Apparent
1 and 3 phase
Range
See remark
Uncertainty (CMC)
0,10%
Remarks/ref. to internal procedure: BL08.07.01
cosφ = -1 til 1
f = 45 Hz til 70Hz
I = 0,01 A til 120 A
U = 5 V til 520 V
Termocouple (TC) Source, cal of meter
Range
-250 °C to 2316 °C
Uncertainty (CMC)
From U=0,11 °C to 0,65 °C
Remarks/ref. to internal procedure: BL08.04.01
Termocouple (TC) Measure, cal of source
Range
-250 °C to 2316 °C
Uncertainty (CMC)
From U=0,11 °C to 0,65 °C
Remarks/ref. to internal procedure: BL08.05.01
Resistance thermometer Source, cal of meter
Range
-200 °C to 630 °C
Uncertainty (CMC)
From U=0,02 °C to 0,18 °C
Remarks/ref. to internal procedure: BL08.04.01