The laboratory meets the requirements in

NS-EN ISO/IEC 17025:2017




Accreditation includes:
The administrative / geographical unit:
Nordic Lift AS
Østre Rosten 72
7075 Tiller



Field testing laboratory K05 Mechanical quantities

Bremseprøver - Lastcelle (transducer)

Range
Uncertainty (CMC)
Range
1 - 8 kN
Uncertainty (CMC)
± 0,018 kN ved 1 kN
Range
Uncertainty (CMC)
± 0,047 kN ved 8 kN

Remarks/ref. to internal procedure: The object is calibrated with an electronic transducer. This is used to gradually apply a given load that is compared with the value measured by the unit under test (the object).

Brake tester - Dead weight

Range
Uncertainty (CMC)
Range
1 - 8 kN
Uncertainty (CMC)
± 0,014 kN ved 1 kN
Range
Uncertainty (CMC)
± 0,054 kN ved 8 kN

Remarks/ref. to internal procedure: The object is calibrated with a weights. These are used to gradually apply a given load which is compared with the value measured by the unit under test (the object).
Field testing laboratory K07 Fluid quantities

Exhaust gases analyser - Carbon monoxide

Range
Uncertainty (CMC)
Range
0,8 - 4,2 vol%
Uncertainty (CMC)
± 0,04 vol% ved 0,97 vol%
Range
Uncertainty (CMC)
± 0,04 vol% ved 4,01 vol%

Remarks/ref. to internal procedure: Objektet kalibreres ved hjelp av nullpunkt og to referansegasser med forskjellige konsentrasjoner, en med lav konsentrasjon og en med høy konsentrasjon.

Exhaust gases analyser - Carbon dioxide

Range
Uncertainty (CMC)
Range
4,3 - 14,6 vol%
Uncertainty (CMC)
± 0,2 vol% ved 5,0 vol%
Range
Uncertainty (CMC)
± 0,2 vol% ved 14,0 vol%

Remarks/ref. to internal procedure: The object is calibrated using a zero point and two reference gases with different concentrations, one with low concentration and one with high concentration.

Exhaust gases analyser - Hydrocarbons

Range
Uncertainty (CMC)
Range
700 - 3500 vol-ppm
Uncertainty (CMC)
± 7 vol-ppm ved 777 vol-ppm
Range
Uncertainty (CMC)
± 18 vol-ppm ved 3286 vol-ppm

Remarks/ref. to internal procedure: The object is calibrated using a zero point and two reference gases with different concentrations, one with low concentration and one with high concentration.
Field testing laboratory K08 Optical quantities

Diesel smoke meter - K-value

Range
Uncertainty (CMC)
Range
0,80 - 4,10 m-1
Uncertainty (CMC)
± 0,04 m-1 ved 0,82 m-1
Range
Uncertainty (CMC)
± 0,08 m-1 ved 4,08 m-1

Remarks/ref. to internal procedure: The object is calibrated using a zero point and 2 or more reference filters (with low and high opacity).

Headlamp beam tester

Range
Uncertainty (CMC)
Range
0 mm/m til 20,0 mm/m (nedvinkling)
Uncertainty (CMC)
± 1,4 mm/m

Remarks/ref. to internal procedure: The object is calibrated using a calibrated laser that is placed perpendicular to the light box. The laser light, which consists of a cross, is sent in and focused through the lens of the light box. The light box has a horizontal centerline. The deviation between the laser light and the center line in the horizontal direction is determined.