Object
Electrical and electronic equipment
Parameter
Immunity to conducted disturbances, induced by radio-frequency fields
Reference standard
NEK EN 61000-4-6
Internal method identity
M-EMC-TP-2025-3
Comment
EN 61000-4-6:2023
Object
Electrical and electronic equipment
Parameter
Power frequency magnetic field immunity test
Reference standard
NEK EN 61000-4-8
Internal method identity
TP-C-Power-frequency magnetic field
Object
Electrical and electronic equipment
Parameter
Voltage dips, short interruptions and voltage variations immunity tests
Reference standard
IEC 61000-4-11
Internal method identity
M-EMC-TP-2025-13
Object
Electrical and electronic installations in ships
Parameter
Electromagnetic compatibility (EMC)
Reference standard
IEC 60533
Internal method identity
M-EMC-TP-2025-3
M-EMC-TP-2025-4
M-EMC-TP-2025-5
M-EMC-TP-2025-9
M-EMC-TP-2025-10
M-EMC-TP-2025-13
M-EMC-TP-2025-2
M-EMC-TP-2025-8
Comment
Corresponds to NEK IEC 60533:2015.
EMC testing according to chapter 6, radiated emissions from 150 Khz to 30 Mhz is not accredited.
Object
Electrical, electronic and programmable equipment and systems
Parameter
Environmental test specification for electrical, electronic
and programmable equipment and systems specification
Reference standard
DNV-CG-0339
Internal method identity
M-EMC-TP-2025-1
M-EMC-TP-2025-3
M-EMC-TP-2025-4
M-EMC-TP-2025-5
M-EMC-TP-2025-9
M-EMC-TP-2025-10
M-EMC-TP-2025-2
M-EMC-TP-2025-8
Comment
EMC testing according to clause 4/5, table 2,3/12,13/14 included except Clause 14.6.
Object
Electrical/electronic equipment
Parameter
Electromagnetic compatibility (EMC). Generic standards. Immunity for residential, commercial and light-industrial environments
Reference standard
EN 61000-6-1
Internal method identity
M-EMC-TP-2025-4
M-EMC-TP-2025-5
M-EMC-TP-2025-9
M-EMC-TP-2025-10
M-EMC-TP-2025-13
Comment
Includes:
IEC 61000-6-1:2019.
Object
Electrical/electronic equipment
Parameter
Electromagnetic compatibility (EMC). Generic standards. Emission standard for industrial environments
Reference standard
EN 61000-6-4
Internal method identity
M-EMC-TP-2025-2
M-EMC-TP-2025-8
Comment
Includes:
EN 61000-6-4 +A1/2011.
IEC 61000-6-4:2019.
Object
Electrical/electronic equipment
Parameter
Immunity to RF electromagnetic radiation
Reference standard
IEC 61000-4-3
Internal method identity
M-EMC-TP-2025-9
Comment
Including A1:2007+A2:2010
Object
Electrical/electronic equipment
Parameter
Surge immunity test
Reference standard
IEC 61000-4-5
Internal method identity
M-EMC-TP-2025-10
Comment
Including A1:2017. 3 phase power solutions not included.
Object
Electrical/electronic equipment
Parameter
Electromagnetic compatibility (EMC). Generic standards. Emission standard for residential, commercial and light-industrial environments
Reference standard
EN 61000-6-3
Internal method identity
M-EMC-TP-2025-2
M-EMC-TP-2025-8
Comment
Includes:
EN 61000-6-3:2007 +A1/2011 and AC:2012.
IEC 61000-6-3:2021.
Object
Electrical/electronic equipment
Parameter
Immunity to electrostatic discharge (ESD)
Reference standard
IEC 61000-4-2
Internal method identity
M-EMC-TP-2025-5
Comment
Harmonized as EN 61000-4-2:2009
Object
Electrical/electronic equipment
Parameter
Electrical fast transient/burst immunity test
Reference standard
IEC 61000-4-4
Internal method identity
M-EMC-TP-2025-5
Object
Electrical/electronical equipment
Parameter
Generic standards - Immunity standard for industrial environments
Reference standard
EN 61000-6-2
Internal method identity
M-EMC-TP-2025-4
M-EMC-TP-2025-5
M-EMC-TP-2025-9
M-EMC-TP-2025-10
M-EMC-TP-2025-13
Comment
Includes:
EN 61000-6-2:2005 + AC:2005
IEC 61000-6-2:2019.
Excluded:
Part 4-20, 4-21, 4-22 and 4-34
Object
Electrical/electronical equipment
Parameter
Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment.
Reference standard
MIL-STD-461G
Internal method identity
M-EMC-2025-1
M-EMC-2025-2
M-EMC-2025-4
M-EMC-2025-6
M-EMC-2025-7
M-EMC-2025-8
M-EMC-2025-9
M-EMC-2025-10
M-EMC-2025-11
M-EMC-2025-12
M-EMC-2025-13
M-EMC-2025-14
Comment
MIL-STD 461G
RE101, RE102, RE103,
RS101, RS103, CS101,
CS114, CS 115, CS116,
CS118, CE101, CE102
Object
Industrial, scientific
and medical (ISM)
radio-frequency
equipment
Parameter
Radio disturbance
characteristics - Limits
and methods of
measurement
Reference standard
EN 55011
Internal method identity
M-EMC-TP-2025-2
M-EMC-TP-2025-8
Comment
+A2:2021
Testing according to group 1 equipment in EN 55011.
Object
Information technology equipment
Parameter
Immunity characteristics - Limits and methods of measurement
Reference standard
EN 55024
Internal method identity
Selection of basic tests
Comment
Corresponding to IEC 55024
Object
Maritime navigation and radiocommunication equipment and systems
Parameter
Electromagnetic
compatibility (EMC)
Reference standard
IEC 60945
Internal method identity
M-EMC-TP-2025-2
M-EMC-TP-2025-3
M-EMC-TP-2025-8
M-EMC-TP-2025-9
M-EMC-TP-2025-5
M-EMC-TP-2025-10
M-EMC-TP-2025-4
Comment
Including Corr 1:2008. EMC testing according to clause 9 & 10. (10.7 not included)
Object
Multimedia equipment
Parameter
Electromagnetic compatibility
Reference standard
EN 55032
Internal method identity
M-EMC-TP-2025-2
M-EMC-TP-2025-8
Comment
Harmonised standard ref. Official journal. EN 55032:2015 and
EN 55032:2015/A11:2020. Corresponding to CISPR 32:2012.
The accreditation does not include Annex C.3.7, C.3.8, C.4.2, C.4.3 & Annex H
Object
Test specification for
Type Approval
Parameter
Methods of testing and required results
Reference standard
International Association
of Classification Societies
(IACS) E10
Internal method identity
M-EMC-TP-2025-1
M-EMC-TP-2025-3
M-EMC-TP-2025-4
M-EMC-TP-2025-5
M-EMC-TP-2025-9
M-EMC-TP-2025-10
M-EMC-TP-2025-2
M-EMC-TP-2025-8
Comment
Including Corr. 1 JAN 2022.
EMC testing according to clause 3/4 for DC supply/ 9/10/13/14/16/17/18 exluding 3 phase power/19/20 is included for this rev 9 of E10.