You are here:

Accreditation scope for

TEST 343

Salmax Research AS

Sentrumsgata 6
7970 Kolvereid

Telephone: 480 20 669
E-mail: Jakob.mo@salmax.no
Internet: http://www.salmax.no
The laboratory meets the requirements in

NS-EN ISO/IEC 17025:2017




Accreditation includes:
The administrative / geographical unit:
Salmax Research AS
Sentrumsgata 6
7970 Kolvereid



Permanent facility
P12 Chemical analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Drinking water
Parameter
Determination of color
Reference standard
NS-EN ISO 7887
Internal method identity
D77
Comment
Method C Spectrophotometric measurement
Object
Drinking water
Parameter
pH
Reference standard
NS-EN ISO 10523
Internal method identity
D70
Comment
Electrochemical measurement
Object
Drinking water
Parameter
Determination of turbidity
Reference standard
NS-EN ISO 7027-1
Internal method identity
D78
Comment
Nephelometric method
Object
Drinking water
Parameter
Determination of electrical conductivity
Reference standard
NS-EN 27888
Internal method identity
D82
Comment
Replaces ISO 7888:1985 Potentiometric measurement
P16 Microbiological analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Drinking water
Parameter
Detection and enumeration of intestinal enterococci
Reference standard
ISO 7899-2
Internal method identity
D7
Comment
MF-method
Object
Drinking water
Parameter
Enumeration of Escherichia coli and coliform bacteria
Reference standard
NS-EN ISO 9308-2
Internal method identity
D66
Comment
MPN-method (Colilert)
Object
Drinking water
Parameter
Enumeration of culturable micro-organisms
Reference standard
NS-EN ISO 6222
Internal method identity
D67
Comment
Cultivation, embedding